Skip to main content

GMJ Academy

Sterilization, Disinfection and Reprocessing [PS-07-EN]

Inadequate reprocessing turns instruments into infection vectors. This course covers sterilisation cycles, disinfection levels, reprocessing validation, and the audit evidence ... Show more
Instructor
GMJ Academy
0
0 reviews
  • Description
  • Curriculum
  • Reviews
test

Sterilization, Disinfection and Reprocessing [PS-07-EN]

Healthcare-associated infections linked to inadequately reprocessed instruments remain a preventable yet persistent threat to patient safety worldwide. The WHO estimates that hundreds of millions of patients are affected by healthcare-associated infections each year, and a significant proportion of these events are directly attributable to failures in device reprocessing — from incomplete cleaning cycles to misclassified disinfection levels. In Georgia and across the South Caucasus, accelerating hospital accreditation processes and increasing procedural volumes in endoscopy, surgery, and interventional specialties have placed central sterile supply departments under intensifying scrutiny. Clinicians, infection prevention officers, and sterile processing personnel require a precise, standards-grounded competency to ensure every reprocessed device is safe before it reaches the next patient.

This course is built on the Spaulding classification framework — the internationally accepted taxonomy that assigns critical, semi-critical, and non-critical devices to corresponding levels of reprocessing stringency — and integrates current guidance from WHO, the Joint Commission International (JCI), ISO 17664, and EN ISO 15883 on washer-disinfector validation. Instructional content is delivered through applied case scenarios drawn from real-world reprocessing failures, audit findings, and corrective action reports, enabling participants to translate regulatory requirements into verifiable departmental practice. Assessment is criterion-referenced and aligned to the competency standards expected by international accreditation surveyors.

By the end of this course, participants will be able to:

  • Distinguish between the three tiers of the Spaulding classification and assign any medical device to the correct reprocessing category based on its intended tissue contact and associated infection risk.
  • Implement a compliant sterilization cycle — including pre-cleaning, manual and automated cleaning, inspection, packaging, steam or low-temperature sterilization, and storage — in accordance with ISO 17664 and EN ISO 15883 requirements.
  • Evaluate the appropriate disinfection level (high, intermediate, or low) for flexible endoscopes, respiratory therapy equipment, and surface-contact items, applying accepted chemical concentrations, contact times, and temperature parameters.
  • Apply reprocessing validation methodology, including biological and chemical indicator interpretation, cycle parametric release criteria, and documentation standards required to demonstrate ongoing process control to ISO and JCI surveyors.
  • Analyze audit evidence for common reprocessing deficiencies — including point-of-use pre-treatment failures, inadequate luminal flushing, and expired sterilant monitoring — and construct a structured corrective action plan that addresses root cause rather than surface findings.
  • Design a departmental audit tool for central sterile supply departments that captures critical control points, supports traceability of sterilized loads to individual patients, and generates the documentary record required for accreditation review.

Who Should Attend

This course is designed for infection prevention and control nurses, central sterile supply technicians, operating theatre charge nurses, and hospital quality and patient safety officers working in acute-care hospitals, day-surgery centers, and endoscopy units. It is equally relevant to clinical leads and department managers who bear regulatory accountability for reprocessing compliance under national licensing standards or JCI accreditation frameworks. Professionals in Georgia and neighboring South Caucasus countries whose institutions are pursuing or maintaining international accreditation will find the audit-readiness components of particular operational value.

Course Structure

The course is delivered entirely online through GMJ Academy’s asynchronous learning environment and requires approximately four to five hours of directed study, including video-based instruction, interactive case analysis, and a structured knowledge assessment with a minimum passing threshold of 80%. Successful completion awards verified CME/CPD credit recognized by the continuing professional development framework of the Medical Association of Georgia.

Share
Course details
Duration 120m
Lectures 11
Quizzes 3
Basic info
A structured course on device reprocessing: an introduction, seven teaching chapters with worked cases, and a certification test.
Intended audience
Sterile-processing staff, nurses, physicians, and infection-control teams.
Sterilization, Disinfection and Reprocessing [PS-07-EN]